Release: Australia · Updated: 2026-03-12 · Official documentation · View source

Breakdown and indicator Performance Analytics properties

These properties set limits on breakdown elements and indicators, mostly in the context of visualizations.

PropertyDescription
com.snc.pa.scoresheet.max\_elementsMaximum number of breakdown elements of a breakdown that can be shown in a scoresheetDefault: 500
com.snc.pa.breakdown\_element\_cutoff

Maximum number of elements that a breakdown can have where the Analytics Hub and KPI Details show its scoreless elements.

An element is scoreless when it meets one of these conditions:

  • For real-time scores, the element has never had a score.

  • For a formula indicator, the element has never had a score in one or more of the contributing indicators.

  • For the collected scores of an automated indicator, the element has never had a score. However, if the number of elements that would still be displayed exceeds the com.snc.pa.breakdown_element_cutoff value, only the elements that have a score or change value on the selected date are displayed. For more information and examples, see Collected scores and com.snc.pa.breakdown_element_cutoff.

Note: This parameter does not affect whether unmatched elements are shown.

Default: 50

com.snc.pa.scorecards.max\_breakdown\_elements

Maximum number of breakdown elements in Analytics Hub lists

Default: 1000

Maximum: 10,000. Any value set above 10,000 is treated as 10,000.

Tip: If this value is not high enough for your indicators, consider redesigning your Performance Analytics solution.

com.snc.pa.scorecard.breakdown.chart.max\_rowsNumber of breakdown elements in visualizationsDefault: 10
com.snc.pa.thresholds.frequency\_intervals\_in\_the\_past\_limitMaximum number of frequency intervals in the past that a threshold check job analyzesDefault: 2
com.snc.pa.scorecard.max\_record\_numNumber of records to be loaded automatically on the records tab of the Analytics Hub for a single indicator. If the number of records exceeds the value of this property, records are not automatically loaded. In this case, the user is presented with a message and a button to load all records. Default: 50,000
com.snc.pa.breakdown\_element\_ui\_max\_recordsDeprecated in Analytics Hub. Limit for the number of elements to be fetched for a breakdown. Used for the lookup fields \(breakdown dashboard, old detailed scorecard, and so on.\) Default: 100
com.snc.pa.target\_batch\_operation\_limitApplies only to KPI Details: The maximum number of targets that can be inserted or updated in one bulk action on the Targets Configuration page. If you face timeouts while inserting or updating targets in bulk, consider reducing this limit. Default: 100
com.snc.pa.widget.max\_widget\_indicatorsMaximum number of widget indicators, in addition to the main indicator that can be added to a widgetDefault: 7
com.snc.pa.widgets.respect\_aclRestrict widget visibility following the ACLs of indicators and breakdowns. True\|false.- Default on new instances: true - Default on upgraded instances from before Quebec: false

Parent Topic:Performance Analytics properties